		jpporto01
		
		(usa Ubuntu)
		
		Enviado em 11/01/2021 - 13:15h 
		Realizei o smartctl para ver possíveis erros e o resultado foi esse:
=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 3.5
Device Model:     ST1000DM010-2EP102
Serial Number:    Z9ACH30X
LU WWN Device Id: 5 000c50 0a2986559
Firmware Version: CC43
User Capacity:    1.000.204.886.016 bytes [1,00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s)
Local Time is:    Mon Jan 11 13:09:25 2021 -03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(    0) seconds.
Offline data collection
capabilities: 			 (0x73) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					No Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 103) minutes.
Conveyance self-test routine
recommended polling time: 	 (   2) minutes.
SCT capabilities: 	       (0x1085)	SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   078   063   006    Pre-fail  Always       -       59526872
  3 Spin_Up_Time            0x0003   099   097   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   080   080   020    Old_age   Always       -       20976
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   081   060   045    Pre-fail  Always       -       161576263
  9 Power_On_Hours          0x0032   094   094   000    Old_age   Always       -       6126
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   080   080   020    Old_age   Always       -       20948
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   088   088   000    Old_age   Always       -       12
188 Command_Timeout         0x0032   100   099   000    Old_age   Always       -       0 0 21
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   062   051   040    Old_age   Always       -       38 (Min/Max 38/38)
193 Load_Cycle_Count        0x0032   090   090   000    Old_age   Always       -       20991
194 Temperature_Celsius     0x0022   038   017   000    Old_age   Always       -       38 (0 17 0 0 0)
195 Hardware_ECC_Recovered  0x001a   003   001   000    Old_age   Always       -       59526872
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       6055h+12m+51.003s
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       27892969438
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       27663463425
SMART Error Log Version: 1
ATA Error Count: 12 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 12 occurred at disk power-on lifetime: 2685 hours (111 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 10 ff ff ff ef 00      00:26:24.081  READ DMA EXT
  35 00 08 d8 65 57 e9 00      00:26:24.080  WRITE DMA EXT
  25 00 08 98 01 a0 e0 00      00:26:24.071  READ DMA EXT
  35 00 08 90 58 65 e0 00      00:26:24.071  WRITE DMA EXT
  35 00 08 a0 37 5f e0 00      00:26:24.071  WRITE DMA EXT
Error 11 occurred at disk power-on lifetime: 2685 hours (111 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 10 ff ff ff ef 00      00:26:21.583  READ DMA EXT
  35 00 08 a8 8a 07 e0 00      00:26:21.582  WRITE DMA EXT
  25 00 08 ff ff ff ef 00      00:26:21.569  READ DMA EXT
  35 00 08 68 f8 88 e1 00      00:26:21.568  WRITE DMA EXT
  25 00 08 e8 7c f0 e0 00      00:26:21.518  READ DMA EXT
Error 10 occurred at disk power-on lifetime: 2685 hours (111 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 10 ff ff ff ef 00      00:26:19.242  READ DMA EXT
  25 00 08 a8 e0 cc e3 00      00:26:19.235  READ DMA EXT
  25 00 08 38 99 7c e0 00      00:26:19.084  READ DMA EXT
  35 00 08 e8 5f 65 e0 00      00:26:19.084  WRITE DMA EXT
  35 00 10 90 37 5f e0 00      00:26:19.084  WRITE DMA EXT
Error 9 occurred at disk power-on lifetime: 2685 hours (111 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 10 ff ff ff ef 00      00:26:16.820  READ DMA EXT
  25 00 80 ff ff ff ef 00      00:26:16.793  READ DMA EXT
  25 00 00 ff ff ff ef 00      00:26:16.784  READ DMA EXT
  25 00 00 ff ff ff ef 00      00:26:16.783  READ DMA EXT
  25 00 00 ff ff ff ef 00      00:26:16.782  READ DMA EXT
Error 8 occurred at disk power-on lifetime: 2685 hours (111 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 10 ff ff ff ef 00      00:26:08.656  READ DMA EXT
  35 00 08 08 84 ba e3 00      00:26:08.656  WRITE DMA EXT
  35 00 10 10 3f 62 e0 00      00:26:08.654  WRITE DMA EXT
  35 00 00 ff ff ff ef 00      00:26:08.653  WRITE DMA EXT
  35 00 00 ff ff ff ef 00      00:26:08.653  WRITE DMA EXT
SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Interrupted (host reset)      00%      6126         -
# 2  Short offline       Completed without error       00%      6126         -
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.